Automatic Potentiometric Titrator

Link Copied
0.5 - 5 Lac / Piece
Business Type Manufacturer, Exporter, Supplier
Type Automatic Potentiometric Titrator
Material Composite Differential Electrode Amplifier Unit
Usage TAN And TBN Analysis For Oil Samples
Click to view more

Product Details

Features
User-friendly Design, Alphanumeric Entry, Multiple Endpoint Evaluation, Error Beeps, Linearity And RSD Calculation
Compliance
ASTM D664, D2896 & D4739
Start Criteria
ML, MV, PH For Initial Fast Dosing
Formulae
Three In Normality Mode, Eight In Sample Mode
RSD Calculation
Mean And RSD Of Any Five Readings

Feature's :  

Advanced Microcontroller-based user-friendly, state-of-the-art product design.User interactive software in dialogue mode for ease of operation with protection against invalid entries.Alphanumeric entry of Sample Name, Titrant Name, Sample Number, Type of Electrode used for authentication.Daily Auto Incremented Titration number and factory-entered CUSTOMER NAME and Instrument Serial Number on report printouts make the system foolproof and GLP compliant.User selectable End Point evaluation up to 10 EP during titration, and calculation by first, last, largest, all or selected EP with display of results and printout.Composite differential Electrode Amplifier unit for Potentiometric and Voltametric/KF Titrations, with connectivity to various Electrodes & Temperature Sensor PT-100.Auto evaluation report for multi EP samples Ep1, Ep2, EP2-EP1 etc. available.Compliant to ASTM D664, D2896 & D4739 for TAN and TBN analysis for oil samples.Start criteria with respect to mL, mV, pH for initial fast dosing to reduce titration time.Stop criteria with respect to mL, mV, pH, and slope. The titration process ends after the desired endpoint or set value.Wide range of parameter selection enables user to choose size of dosing, delay time between steps, or complete automatic selection in ASD method.Titration can be started with last titration parameters. Display of last titration parameters while entering or running method.Display of stir time after pre dispensing.Error beeps in case of wrong entries.Three formulae in Normality mode for w/w, w/v, w/w and third to verify old Normality.Eight formulae in sample mode for different units to find purity or concentration.Formula number 6 and 7 for TAN TBN Titration and formula number 8 is for user-defined unit.Buzzer indication at each endpoint.Short result report available on display printout, can be taken for full document report or Individual reports as short result report, parameter report, data report & graphics.System Linearity:The instrument has facility to store 10 results.Linearity of any five results can be obtained from the results stored.No need to do manual calculation or use any other device for calculations.Relative Standard Deviations:Mean of any five readings can be obtained from the results stored.RSD of any five results can be obtained from the results stored.No need to do manual calculation or use any other device for calculations.

Yes! I am interested

Looking for "Automatic Potentiometric Titrator" ?

Piece

Explore More Products



Close

Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us